GE Monogram ZGU48L6RDSS Oven User Manual


 
Monogram.
Specification Created 7/01
For answers to your Monogram,
®
GE Profile
or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center
®
service, 800.626.2000.
ZGU48L6RDSS48" Professional Gas Cooktop
Dimensions and Specifications (in inches)
Advance Planning:
Refer to dimensional drawings for appropriate
placement and necessary clearances when
planning the installation.
Cabinetry cannot be installed directly above
the cooktop.
This cooktop requires the installation of a vent
hood, 30" to 36" above the surface.
The vent hood must be at least 24" deep.
The vent hood must be the same width as
the cooktop.
The vent hood blower should provide at least
800 CFM and up to 1200 CFM.
Choose a vent hood with 800CFM for best
performance when operating the grill
Working areas adjacent to the range should
have 18" minimum clearance between
countertop and cabinet bottom.
Clearance between cooktop and side wall or
combustible material must be at least 12" on
each side.
This cooktop requires 8" free space below
the countertop.
If the cooktop is installed in an island:
Allow 12" min. clearance at the back to
combustible materials.
Allow 36" min. above the cooking surface to
combustible materials.
Installation must conform with local codes. In
the absence of local codes, the gas cooktop
must comply with the National Fuel Gas Code,
ANSI Z223.1, latest edition.
A.G.A. approved
48" Wide Hood
30" Min.
36" Max.
18" Min.
12" Min. to
Combustible
Material
Each Side
36" Min. to
Combustible
Material From
Cooking
Surface
13" Max.
17"
22-3/4" Min.
Electric/Gas
Supply
46-1/8"
7/8"
8"
2-1/2"
2"
Cooking Surface
Low Back
High
Shelf
26-5/8"
10"
2-1/2"
21-1/4"
12"
36" Min.
to Combustibles
Island Trim
12" Min. to Combustibles
Without Backguard
36" Min.
to Combustibles
R
Listed by
Underwriters
Laboratories