STEP 1 REMOVE PACKAGING
CAUTION: Refrigerator is much heavier at the
top than at the bottom – be careful when moving.
When using a hand truck, handle from side only.
PRUDENCE: Le réfrigérateur est beaucoup plus
lourd en haut qu'en bas. Il faut être prudent lors des
déplacements. Si un diable est utilisé, il faut soulever
le réfrigérateur sur le côté seulement.
• Carefully cut banding at the top and bottom, remove
outer carton.
• Slide out back corner posts (2).
• Slide carton off top of cabinet.
NOTE: IT IS NOT NECESSARY TO LAY CABINET
DOWN IN ORDER TO REMOVE SKID!
• The unit is secured to the skid with 4 slotted tie-down
straps. Remove the four 5/16" bolts from the base
channels in the tie-downs.
• Remove the four 7/16"
bolts securing the straps
to the skid.
CAUTION: DO
NOT ATTEMPT TO
ROLL UNIT OFF SKID.
PRUDENCE: IL
NE FAUT PAS ESSAYER
DE FAIRE ROULER LE
RÉFRIGÉRATEUR POUR
L'ENLEVER DE LAY
PALETTE.
STEP 2 INSTALL WATER LINE
• A cold water supply is required for automatic ice-
maker operation. The water pressure must be be-
tween 40 and 120 p.s.i.
• Route 1/4" OD copper tubing between house cold
water line and the water connection location.
• Copper tubing should be long enough to extend to
the front of the refrigerator. Allow enough tubing to
accommodate bend leading into the water line
connection.
Shut off the main water supply.
Turn on the nearest faucet long enough to clear the
line of water.
• Install a shut-off valve between the icemaker water
valve and cold water pipe in a basement or cabinet.
The shut-off valve should be located where it will be
easily accessible.
NOTE: It is best to install the valve into a vertical water
pipe. If you install the valve into a horizontal water
pipe, make the connection at the top or side, to
avoid drawing off any sediment from the water pipe.
• Drill a 1/4" hole in the water pipe.
• Fasten the shut-off valve to the pipe with pipe clamp.
• Tighten the clamp screws until the sealing washer
begins to swell. Do not over tighten.
• Place a compression nut and ferrule (sleeve) onto the
end of the tubing and connect it to the shut-off valve.
Make sure the tubing is fully inserted into the valve
and ferrule is tightened.
• Turn on the main water supply and flush debris. Run
about a quart of water through the tubing into a
bucket. Shut off water supply at the shut-off valve.
NOTE: Saddle type shut-off valves are included in
many water supply kits. Before purchasing, make sure
a saddle type valve complies with your local plumbing
codes.
Saddle Type
Shutoff Valve
Compression Nut
Ferrule
(Sleeve)
Outlet Valve
Packing Nut
10
Remove
Tie-Downs
Toekick
• Support blocks on the bottom of the refrigeration
case must be removed before sliding unit off skid or
damage will occur. Carefully, tilt refrigerator and
slide blocks out from beneath, slide unit off skid.
• Remove toekick. Set aside for final installation.
Floor
Copper Tubing