PROBLEM POSSIBLE CAUSE
FAN DOES NOT • A fuse may be blown or a circuit breaker tripped. Replace fuse or
OPERATE WHEN reset circuit breaker.
THE SWITCH IS ON
FAN FAILS TO • Fan blade striking the hood shell.
CIRCULATE AIR
• Excessively soiled filter should be checked and corrected before
using the hood again.
FAN OPERATES BUT • Check to be sure the filter is clean. If replacing the filter does not
MOVES AIR SLOWER correct the problem, call for service.
THAN NORMAL
FAN KEEPS GOING •The motor is probably overheating and turning itself off. This can
OFF AND ON be harmful to the motor. Check to be sure the filter is clean. If off
and on cycling continues, call for service.
FAN FILTER LIGHT IS • Filters are not in place or not properly seated. Replace the filters
ON OR IS BLINKING or if the filters are in, adjust them in place.