Grindmaster G235-2B Coffeemaker User Manual


 
Page 12 G & MG Series Granita Machine
Maintenance (con’t)
Cleaning the Condenser (Monthly)
This cleaning should be done monthly or more often if necessary.
In order to guarantee an efficient refrigerating system, it is essential that the
condenser be properly cleaned at regular intervals, according to the following
procedures:
Unplug the machine.
Remove the back panel and filter. Using a dry brush or vacuum, remove the dust that
has accumulated between the fins of the condenser (see fig HH).
Replacing the Lightbulbs (As Needed)
• Unplug the machine.
Lid Lights
• Unplug the cord to the lid and remove the lid from the machine.
In order to access the lightbulb in the merchandising cover, insert
a quarter in the slot on the small panel on the top of the cover (DA)
and rotate the quarter to pop the panel open (see fig. II).
Holding the merchandising cover with the top open, carefully remove the
lightbulb (see fig. JJ).
Insert the new bulb and replace the light cover.
• Place lid on machine and plug lid cord back into lid.
Rear Merchandiser Lights
In order to access the lightbulb from the rear back-lit merchandiser (BB),
remove the rear merchandiser by sliding it upwards (see fig. KK).
NOTE: Some units may have dual rear backlit merchandiser panels, these
function in the same manner as the single panel rear merchandisers.
Then remove the lightbulb(s) (BA) (see fig. LL).
Insert the new bulb(s) (BA).
Reassemble the rear back-lit merchandiser (AA) making sure that its slots
are inserted properly in the relevant brackets (CA) (see fig. LL).
Plug machine into dedicated outlet.
(Figure II)
(Figure JJ)
(Figure KK)
(Figure LL)
(Figure HH)