Haier HHX6130 Ventilation Hood User Manual


 
English
Hood Installation
Note: All wiring installation must comply with local and national electrical
code regulations.
1. Transfer mounting holes to wall where hood is to be mounted.
2. Lift the hood into position and guide the electrical cable
through the electrical cable clamp on the hood.
3. Securely fasten the four wood screws.
4. Secure the electrical cable in the cable clamp while allowing sufficient length in the
hood to connect the field wires to the hood wires. Attach damper to the top of the hood.
5. Attach ductwork and use duct tape to seal all joints.
6. After turning all range hood switches to the OFF position, turn the power ON and test
your installation.
Use and Care
Aluminum Filter
For highest efficiency, this filter should be removed and cleaned periodically. Soak the filter
in hot water and mild soap or detergent. Rinse thoroughly and repeat if necessary.
The aluminum filter may be cleaned in the dishwasher. Heavy grease buildup may not
be cleaned easily, thus the filter may need to be replaced.
Charcoal Filter
Inspect this filter periodically. This filter cannot be cleaned and must be replaced when
it becomes saturated. Check with your local retailer or dealer to purchase.
Light Bulb
Use only halogen MR-16 type bulbs. (Not shipped with range hood.)
Exterior Surface
Wipe the range hood exterior with a soft cloth and a mild detergent suitable for painted
surfaces. Do NOT use abrasive materials such as steel wool pads or scouring powders.
Repair or Replacement Parts
Warning! Disconnect range hood from the electrical power supply before servicing.
All parts may be obtained from service centers authorized by Haier, or may be ordered
directly from Haier. When ordering parts, please specify the range hood model number on
the rating label, which is located on the inside of the range hood.