Halsey Taylor OVL-II ESR-Q Water Dispenser User Manual


 
5
OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F
97793C - 10/01
Legend
Item Description
A 3/8 O.D. Tube - Water Outlet Connection
B 3/8 O.D. Tube - Water Inlet Connection
C 1-1/4 O.D. Tube - Waste Tube - Not provided
D Electrical Inlet on Chiller
Figure 8  OVL-II SER-Q/OVL-II ESR-Q Rough-In Dimensions
5. Install the frame assembly squarely in wall opening
with frame upright support edges flush with the
finished wall face. Secure the frame to the wall
through holes with (12) 5/16 bolts or screws (not
provided). Tighten securely.
NOTE: Be sure that frame is squared in location. Do
not use less than required screw quantity
and size.
6. Attach the chiller shelf support rods to the right side
of the frame uprights at the second set of holes
counting from the bottom and to the shelf at the (2)
side holes. Line up the other shelf holes with the
frame bottom holes and fasten the assembly to the
wall opening using appropriately sized screws or
bolts and nuts (not provided).