Troubleshooting
POSSIBLE PROBLEM
Machine will not work
when switched “ON.”
Motor appears to stall
when juicing.
Excess pulp building up
in the Micro Mesh
Filter Basket.
Pulp is too wet and
insufficient juice is
produced.
Juice leaks between the
rim of the Juicer Cover
and the Filter Bowl.
Juice sprays out of spout.
Juice drips out of spout
immediately after juicing.
Machine vibrates
excessively.
EASY SOLUTION
The Safety Locking Arm may not be correctly
engaged. Check to see if Safety Locking Arm
is properly positioned in the two grooves on
either side of the Juice Cover. Refer to pages
5 and 6, Steps 4 and 5.
Wet pulp can build up under the Juicer Cover
if the juicing action is too vigorous. Try slower
juicing action by pushing the Food Pusher
down more slowly. Refer to page 7, Step 4.
Turn OFF and unplug. Remove the Juicer
Cover, scrape off pulp. Reassemble and begin
juicing again. Try alternating vegetable and
fruit varieties.
Try a slower juicing action. Turn OFF and
unplug. Remove Filter Basket and clean mesh
walls with a fine brush. This will remove excess
fiber build-up which could be inhibiting the
juice flow. Refer to pages 7 and 10.
Try a slower juicing action by pushing the
Food Pusher down more slowly. Refer to
page 7, Step 4.
Try a slower juicing action by pushing the
Food Pusher down more slowly. Refer to
page 7, Step 4.
With motor ON, raise and lower Food Pusher in
Feed Chute several times. The pressure forces
remaining pulp and juice out of Filter Bowl.
Build up of pulp in mesh of FIlter Basket. Turn
unit OFF and unplug. Clean Filter Basket. Refer
to page 10.