Harbor Freight Tools 93011 Electric Steamer User Manual


 
SKU 91098
INSPECTION, MAINTENANCE, AND CLEANING
1. WARNING! Make sure the unit is unplugged from its electrical outlet and
thoroughly cooled down before performing any inspection, maintenance, or cleaning
procedures.
2. BEFORE EACH USE, inspect the general condition of the Wallpaper Steamer. Check
for loose screws, misalignment or binding of moving parts, cracked or broken parts,
damaged electrical wiring, and any other condition that may affect its safe operation.
If abnormal noise or vibration occurs, have the problem corrected before further
use. Do not use damaged equipment.
3. Wipe down the unit and dry the accessories with the Rag (10).
4. Areas with hard water, or when using tap water, will eventually leave a scaly film on
the element in the Boiler Unit (8). Use an over-the-counter descaling product to
clean out the Boiler Unit (8). Follow the descaling product manufacturer’s instructions.
PAGE 11
TROUBLESHOOTING
The Boiler Unit (8) fails to produce steam.
1. Check that the Power Cord (12) is properly plugged into the wall outlet and the
Boiler Unit (8).
2. If the safety cut-off engaged, it will need ample time to cool and reset.
3. The safety cut-off device was damaged from working with a tilted unit.
The Boiler Unit (8) leaks steam from the pressure release valve.
1. The pressure release valve is a special low pressure valve that cannot be replaced
by another valve. If steam leaks from the valve, the most likely cause is a blockage
in the steam Hose (4). Allow the unit to cool and check the Hose (4) for blockages.