Henny Penny CW-216 Food Warmer User Manual


 
Model CW-216/CW-114
2-5. DRAIN CONNECTION The drain can be connected to a 1 inch N.P.T. directly below
the water well or to a 3/4 inch N.P.T. from the operator’s side.
We recommend the 1 inch N.P.T. connection as this allows
straight down draining of the water.
2-6. ELECTRIC CONNECTION The display counter warmer is available from the factory wired
for 208 or 230 volts, single phase 3-wire (includes neutral) or
three phase 4-wire (includes neutral) 60 Hertz service. The
proper power service cable must be provided at installation.
Check the data plate on the side panel of the control end to
determine the correct power supply.
This unit must be adequately and safely grounded. Refer
to local electrical codes for correct grounding procedures.
If unit is not adequately grounded, electrical shock could
result.
(FOR EQUIPMENT WITH CE MARK ONLY!)
To prevent electric shock hazard this appliance must be
bonded to other appliances or touchable metal surfaces in
close proximity to this appliance with an equipotential
bonding conductor. This appliance is equipped with an
equipotential lug for this purpose. The equipotential lug is
marked with the following symbol
A separate disconnect switch with proper capacity fuses or
breakers must be installed at a convenient location between the
cabinet and the power source. The field supply wiring to the
cabinet should be an insulated copper conductor rated for 600
volts and 90ºC.
2-4 1004