Henny Penny EEG-142 Fryer User Manual


 
Model EEG-141, 142, 143, 144
Technical Data for CE Marked Products
Nominal Heat Input: Natural (I2H) = 19,8, kW (67,560 Btu/h)
(Net) Natural (I2E) = 19.8 kW (67,560 Btu/h)
Natural (I2E+) = 19.8 kW (67,560 Btu/h)
Natural (I2L) = 19.8 kW (67,560 Btu/h)
Natural (I2HS) = 19.8 kW (67,560 Btu/h)
Liquid Propane (I3P) = 19,8, kW (67,560 Btu/h)
Nominal Heat Input: Natural (I2H) = 21,98 kW (75,000 Btu/h)
(Gross) Natural (I2E) = 21,98 kW (75,000 Btu/h)
Natural (I2E+) = 21,98 kW (75,000 Btu/h)
Natural (I2L) = 21,98 kW (75,000 Btu/h)
Natural (I2HS) = 21,98 kW (75,000 Btu/h)
Liquid Propane (I3P) = 21,98 kW (75,000 Btu/h)
Supply Pressure: Natural (I2H) = 20 mbar
Natural (I2E) = 20 mbar
Natural (I2E+) = 20/25 mbar
Natural (I2L) = 25 mbar
Natural (I2HS) = 25 mbar
Liquid Propane (I3P) = 30/37/50 mbar
Test Point Pressure: Natural (I2H) = 8.7 mbar
Natural (I2E) = 8,7 mbar
Natural (I2E+) = N/A
Natural (I2L) = 8.7 mbar
Natural (I2HS) = 8.7 mbar
Liquid Propane (I3P) = 25 mbar
Injector Size: Natural (I2H) = 2.08 mm
Natural (I2E) = 2.08 mm
Natural (I2E+) = 1.70 mm
Natural (I2L) = 2.30 mm
Natural (I2HS) = 2.30 mm
Liquid Propane (I3P) = 1.30 mm
This appliance must be installed in accordance with the manufacturer’s instructions and the regulations in force
and only used in a suitable ventilated location. Read the instructions fully before installing or using the appliance.