Henny Penny HMI-103 Food Warmer User Manual


 
Model HMI-103/105
2-3. ELECTRICAL CONNECTION The island warmer is available from the factory wired
for 120/208-240 volts (domestic), or 230 volt and 400
volt (international), single or three phase, 3 or 4 wire
plus ground (includes neutral). The proper power
service cable is provided with domestic units, but not
on international units.
This unit must be adequately and safely grounded. Refer
to local electrical codes for correct grounding procedures.
If unit is not adequately grounded, electrical shock could
result.
A separate disconnect switch with proper capacity fuses or
breakers must be installed at a convenient location between
the unit and the power source.
2-4. ELECTRICAL DATA TABLE Model Volts Phase Watts Amps Wires
HMI-103 120/208 1 2400 11.0 3+G
HMI-103 120/208 3 2400 8.0 4+G
HMI-103 120/240 1 2600 11.0 3+G
HMI-103 120/240 3 2600 7.5 4+G
HMI-105 120/208 1 3900 18.0 3+G
HMI-105 120/208 3 3900 13.0 4+G
HMI-105 120/240 1 4200 17.5 3+G
HMI-105 120/240 3 4200 12.0 4+G
HMI-103 230 1 2600 11.3 4+G
HMI-105 400 3 4200 7.8 4+G
2-2 203