Henny Penny OE/OG 301/302/303 Fryer User Manual


 
This section provides troubleshooting information in the form of
an easy-to-read table.
If a problem occurs during the first operation of a new fryer,
recheck the installation per Section 2 of this manual.
Before troubleshooting, always recheck the operating procedure
per Section 3 of this manual.
e
T
LES
In the event of a control system failure, the digital display will
show an “Error Message.” These messages are coded: E5, E4, E6,
ElO, E15, E41, E50, E51, and E53.
en turn
switc
display shows E4, the control board is getting too hot. Check the
louvers on each side of the unit for obstuctions. If E4 persists,
Turn switch to OFF position, then turn switch back to ON. If
display shows E6, thermal sensor must be replaced. Refer to
section 6-4.
button. If high limit does not reset, high limit must be replaced
per section 6-5, or 6-6.
El5
E41, E50,
E5 1, E53
Drain Switch Close drain, using the drain valve handle. If display still shows
Failure
E 15 check drain valve section 6- 13.
Programming Turn switch to OFF, then back to ON. If display shows any of
Failure the error codes, the control panel needs replaced.