Henny Penny OE/OG 301/302/303 Fryer User Manual


 
NG
LE
With switch in
POWER position
and switch light
not illuminated,
fryer is complete
ly inoperative.
With switch in
power position,
switch light is
on, but all other
lights are out ex
cept the pump
will operate.
Shortening will
not heat but
lights are on.
Open Circuit
No power to
board
Faulty Contactor
(elec. model)
Faulty Gas Valve
(gas model)
Faulty Gas
Solenoid (gas
model)
Faulty Probe
Faulty High
Limit
Faulty Drain
Switch
Check to see if unit is plugged in.
Check breaker or fuse at supply box.
Check control panel fuse per Section 6-12.
@ Check POWER switch per Section 6-14. Replace if defective.
.Check voltage at wall receptacle.
Check cord and plug.
Check fuse on PC board.
Check gas valve per Section 6-11.
Check gas solenoid, per Section 6-19.
Check probe per Section 6-4. “Error message” E6.
Check High Limit per Section 6-6, or 6-7. “Error message”
ElO.
Check drain switch per Section 6-13. “Error message” E15.