Page 2 of 2 F-40179 – CE20FD Boilerless Full Size Combi Oven
As continued product improvement is a policy of Hobart, specications are subject to change without notice.
CE20FD BOILERLESS
FULL SIZE COMBI OVEN
Clearance: Left 1", Back 2", Right
2" required, 18" recommended for
service access.
Note: For trolley use –
1) Floor in front of and under combi
must be level.
2) Must have clearance to open
door 140° minimum.
User Responsibility: The product
must be installed, cleaned and
maintained as described in the
Manual furnished with the product.
F-40179 (REV. 06/11) LITHO IN U.S.A. (H-01)
SPECIFICATIONS:
General: Hobart Combi Oven, Electric, Boilerless, 20 level full size
combi.
Construction: All stainless steel interior and exterior, top, rear,
sides, and bottom are fully insulated. All welded stainless steel
cooking compartment. Stainless steel oven door features a large
curved outer glass with enhanced insulation for a cool to touch
exterior, with full length hinged oating inner glass panel. A full
perimeter door gasket with drip tray inside door and oven frame.
Door opens right to left and swings a full 180 degrees. Standard
with trolley insert, preheat bridge and (10) wire racks. Built in wash
arm for automatic cleaning with auto dosing pump, 4-speed auto
reversing fan, (4) halogen ashing door lights, core probe, dual
point door latch connection for a full perimeter sealed connection.
Standard with 7.6" adjustable feet.
Controls: Simple, user friendly digital controls on the right with
large indicative low voltage LCD display - for easy cleaning and
operating pleasure. Manual operation or programmable up to
100 recipes with 10 cooking phases each. Includes Bluetooth
®
communication and recipe software for PC.
Operation: Electric boilerless combi which uses a direct steam
creation method. Hobart’s Boilerless Combi uses optimized cooking
functions for maximum production with minimal energy and water
consumption.
Water: A suitable Hobart Water Treatment System is the recom-
mended minimum to meet the water quality spec. ¾" NSHT cold
water, 30-60 psi and 1" NPT drain connection.
Capacity: Capable of holding: (40) 12" x 20" x 2
1
2" steam table
pans or (20) 18" x 26" sheet pans or (40) 13" x 18" x 1".
Water Quality Specication for Warranty Purposes
The fact that a water supply is potable is no guarantee that it is
suitable for steam generation. All steam equipment is subject to
contamination and failure due to chemical and mineral content
found in water. A suitable Hobart Water Treatment System and
regular lter replacements coupled with routine deliming is the
recommended minimum. Damage as a result of poor water quality
or lack of required owner/operator maintenance is the responsibil-
ity of the owner/operator.
Your water supply must be within these general guidelines:
DYNAMIC WATER PRESSURE 30-60 psig
HARDNESS * less than 3 grains
SILICA less than 13 ppm
TOTAL CHLORIDE less than 30 ppm
Ph RANGE 7-8
CHLORINE & CHLORAMINE 0 ppm
ALKALINITY Less than 20 ppm
TDS Less than 60 ppm
DETAILS AND DIMENSIONS:
UN-DISSOLVED SOLIDS less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount
of chlorination and dissolved gasses. Water supplies vary from
state to state and from locations within a state. Therefore it is
necessary that the local water treatment specialist be consulted
before the installation of any steam generating equipment.
Note:
• Installationofbackowpreventers,vacuumbreakersandother
specic code requirements is the responsibility of the owner
and installer in compliance with local codes.
• Plasticdrainsarenotrecommendedduetoinherentlimited
temperatures of the plastic. The installer may be required to
provide means to reduce water drain temperature to be that of
the condensate temperature of 140°F or less.
NOTICE: Fluorescent lamp in display panel contains a small amount of
mercury. Please dispose of according to local, state or federal laws.
LEGEND:
1. ELECTRICAL
2. DRAIN
3. ALTERNATE DRAIN
4. WATER SUPPLY
Model Width Depth Height Weight
CE20FD 35.4" 45.8" 70.4" 694 lbs.
NOTES:
Amperage values in the table are nominal. Tolerance is +5/-10%.
Convection heater currents must be measured in full power convection heat mode.
Steam generator heater currents must be measured in full power steam mode.
* Recommended size. Always refer to the NEC, state and local codes.
Model Voltage
Amps
(max used)
Watts
Fuse
*
(amps)
CE20FD-1 208/60/3 103.8 37400 150
CE20FD-3 230-240/60/3 93.8-102.1 37400-40700 150
CE20FD-2 480/60/3 45 37400 60