Hobart CG55 ML-CG55480S001 Griddle User Manual


 
– 7 –
ELECTRICAL DATA — TABLE TWO
* Two separate conduit connections must be made; one connection carries 16.2 KW and the other carries 10.8 KW.
** Two separate conduit connections must be made; each connection carries one-half of the rated load.
Rated voltages: 208, 240, 480 VAC; 1- or 3-phase, 50/60 Hz.
CG20
8.0 200-
7 1205
4.0 0.0 4.0
25.0 14.4 14.4 28.9 16.7 16.7 14.4 8.3 8.3 28.8 33.3 16.7
6.0 450 3.0 0.0 3.0
CG41 21.6
200-
7 2100 10.8 5.4 5.4 68.7 68.7 45.2 59.5 59.5 39.0 29.8 29.8 19.5 103.9 90.0 45.0
450
CG50
CG50
16.2 200-
7 3500
5.4 5.4 5.4 45.0 45.0 45.0 39.0 39.0 39.0 19.5 19.5 19.5 77.9 67.5 33.8
*
10.8 400 5.4 0.0 5.4 45.0 26.0 26.0 39.0 22.5 22.5 19.5 11.3 11.3 51.9 45.0 22.5
CG55 12.0
200-
7 1808 4.0 4.0 4.0 33.4 33.4 33.4 28.9 28.9 28.9 14.4 14.4 14.4 57.7 50.0 25.0
450
CG58 16.2
200-
7 2100 5.4 5.4 5.4 45.0 45.0 45.0 39.0 39.0 39.0 19.5 19.5 19.5 77.9 67.5 33.8
450
CG59
32.4 200-
7 4200 5.4 5.4 5.4 45.0 45.0 45.0 39.0 39.0 39.0 19.5 19.5 19.5 77.9 67.5 33.8
** 450
M
O
D
E
L
T
O
T
A
L
K
W
T
E
M
P.
R
A
N
G
E
(°F)
P
R
E
H
E
A
T
T
I
M
E
(MIN.
TO
350°F)
W
A
T
T
S
T
O
H
O
L
D
400°F
PHASE-LOADING AND LINE AMPERES
NOMINAL AMPERES PER LINE
3-PHASE
LOADING
3-PHASE 1-PHASE
KW PER PHASE 208 VOLTS 240 VOLTS 480 VOLTS
L1-L2 L2-L3 L1-L3 L1 L2 L3 L1 L2 L3 L1 L2 L3
208 240 480
V. V. V.