FIG. 9 — CG50 WIRING DIAGRAM - 208, 240 & 480 V., 1 & 3 PHASE
FOR SUPPLY CONNECTIONS USE COPPER WIRE SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL
CODE AND SUITABLE FOR AT LEAST 90°C. (194°F.)
LEAD MARKER NUMBERS ARE THE SAME AS LEAD ITEM NUMBERS UNLESS OTHERWISE SPECIFIED.
208/240 V. WIRING TO BE: 480 V. WIRING TO BE:
10 GA., 532515 - LEADS 1-18 10 GA., 532515 - LEAD 11
18 GA., 532518 - LEADS 19-24 12 GA., 532514 - LEADS 8, 10, & 15-18
14 GA., 529358 - LEADS 1-7, 9, & 11-14
18 GA., 532518 - LEADS 19-24
PHASE WIRING
JUNCTION BOX RIGHT BODY JUNCTION BOX LEFT BODY
SINGLE PHASE: CONNECT WIRES 10 & 12 TO SINGLE PHASE: CONNECT WIRE 18 TO
ONE FIELD LINE WIRE AND WIRES 8 & 17 ONE FIELD LINE WIRE AND WIRES 16 & 15
TO THE OTHER FIELD LINE WIRE. TO THE OTHER FIELD LINE WIRE.
THREE PHASE: CONNECT WIRES 8 & 10 TO L1 THREE PHASE: CONNECT WIRE 18 TO L1
FIELD LINE WIRE, WIRE 17 TO L2 FIELD LINE FIELD LINE WIRE, WIRE 16 TO L2 FIELD LINE
WIRE AND WIRE 12 TO L3 FIELD LINE WIRE. WIRE AND WIRE 15 TO L3 FIELD LINE WIRE.
FOR CONNECTION TO 3-PHASE, 4-WIRE 220 380 V. SYSTEM
2-PHASE PLUG NEUTRAL USED ONLY
CONNECT WIRES 8 & 10 TO NEUTRAL (N) CONNECT WIRE 18 TO NEUTRAL (N)
CONNECT WIRE 12 TO L1 CONNECT WIRE 16 TO L1
CONNECT WIRE 17 TO L2 CONNECT WIRE 15 TO L2
FIELD LINES
L1 & L2 USED
L1
12
17
8
10
L2
N NEUTRAL LINE
FIELD LINES
L1 & L2 USED
L1
16
15
18
L2
N NEUTRAL LINE
FIG. 10 — CG55 WIRING DIAGRAM - 208, 240 & 480 V., 1 & 3 PHASE