Hobart FD500 Garbage Disposal User Manual


 
FD500
FOODWASTE DISPOSERS
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
F-8391 – FD500 Foodwaste Disposers Page 3 of 4
ELECTRICAL CONTROL GROUPS Listed by Underwriters Laboratories Inc., for use with FD Disposers
(50 Hz. Electrical Specifications not submitted for UL Listing.)
Group 2
Includes:
Magnetic Contactors
Pushbutton Start and Stop
Automatic Reversing
NEMA 12 Enclosure
Solenoid Valve
Approximate
Shipping Wt. 31 lbs.
Group 3
Includes:
Magnetic Contactors
Pushbutton Start and Stop
Automatic Reversing
Low Water Pressure Cut-off
Time Delay for water after shut-off
Line Disconnect
Solenoid Valve
NEMA 12 Enclosure
Approximate
Shipping Wt. 38 lbs.
AVAILABLE ELECTRICAL
SPECIFICATIONS
5.H.P., 3 Phase
Hz. VOLTS RATED AMPS
60 200-230/460 12.8/6.4
50 220-240/380-415 11.6/6.7
The slant (/) line indicates the dual voltage operation accomplished by motor lead connections:
follow connecting diagram on motor.
SAMPLE SPECIFICATION
FD-500 — B — 2 (230/60/3)
Electrical Specifications
Electrical Control Group
Accessory Group
Model Number
Cut hole 19" for 18" cone. Hole to be 16" for 15" cone.
Solenoid must be installed in upright position.
Disposer may be easily rotated for better drain line connection.
Center line at wall outlet of trap should not be higher than
center line of disposer discharge opening.
If water pressure is in excess of 60 P.S.I. install a pressure
reducing valve.