– 35 –
TROUBLESHOOTING GUIDE
SYMPTOM
No power when switch is
turned on.
Fryer will not heat.
Fryer continues to heat.
Fryer heats, but will not reach
desired temperature.
Fryer stops heating during
operation.
POSSIBLE CAUSES / SOLUTIONS
Tripped breaker; fuse blown / Verify fryer is plugged in and outlet
has power.
Problem with power switch / Call service.
Gas supply not on or partially on / Verify gas supply valve is full
on / Check hose connection (if applicable).
Verify power is on.
Gas valve in fryer not on / Verify gas valve is on in fryer / Verify
pilot comes on.
Problem with high limit / Call service.
Problem with electrical system / Turn off gas supply and call
service.
Combination valve is stuck in open position / Turn off gas supply
and call service.
Problem with electrical system / Call service.
Gas supply pressure inadequate / Call service.
Tripped breaker, fuse blown / Verify fryer is plugged in and check
circuit breakers and fuse(s).
Check gas supply. Verify pilot is on.
Shortening is too hot, high limit switch is open / Call service.