– 31 –
DAILY FILTERING
WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING,
CLEANING AND SERVICING THE FRYER.
Filtering Guidelines (All Models)
• Stand alone fryers are available in filter-ready and non-filter-ready versions.
• Battery interplumbing is available only on fryers equipped with Filter-In-A-Drawer.
• A cold fryer will not drain properly. Always filter shortening in a liquid state. The shortening under
the cold zone area will remain hard, even if the heat is on for a few minutes. If necessary, use
the cleanout rod to carefully stir the hard shortening to an area above the cold zone (Fig. 7)
where it will melt.
• Filter shortening at least once a day (see Shortening Life on page 33).
Fig. 7
Filter-Ready Fryers (For Use With Mobile Filter Only)
• The Mobile Filter is covered in a separate instruction manual. Follow the instructions accordingly.
OIL LEVEL
COLD ZONE
PL-50580