ALARMS AND ERROR MESSAGES (HGD and HGC Series)
Pilot Out - If the pilot is out, the control displays the following message:
HGD Series - FIrE OUt
HGC Series - PILOT OUT
If no action is taken after 90 seconds an alarm sounds continuously, the heat demand is disabled and
any running cooking cycles are cancelled. The control displays the following message:
HGD Series - Ign LoC
HGC Series - IGNITION LOCKOUT
The fryer must be turned off, then back on before the pilot can be relit and normal fryer functions
resumed. See pages 14 and/or 15 under Startup for lighting instructions pertaining to your particular
model.
Open Probe - If an open probe is detected, the heat demand is disabled and any running cooking cycles
are cancelled. All operator buttons are disabled. The control displays the following message:
HGD Series - Prob
HGC Series - OPEN PROBE
The alarm sounds continuously until the fault clears or the fryer is turned off then back on. If the problem
persists, call service.
Shorted Probe - If a shorted probe is detected, the heat demand is disabled and any running cooking
cycles are cancelled. All operator buttons are disabled. The control displays the following message:
HGD Series - Hi
HGC Series - SHORTED PROBE
The alarm sounds continuously until the fault clears or the fryer is turned off then back on. If the problem
persists, call service.
Hi Temperature - If the actual temperature is greater or equal to 415°F (212°C), the heat demand is
disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control
displays the following message:
HGD Series - Hi
HGC Series - SHORTED PROBE
The alarm sounds continuously until the fault clears or the fryer is turned off then back on. Normal fryer
operations resumes when temperature drops below 415°F (212°C). If the problem persists, call
service.