701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Page 2 of 4 F-8193 – LXi Dishmachine
LXi
DISHMACHINE
CONNECTION INFORMATION
(AFF = ABOVE FINISHED FLOOR)
LEGEND
E1 ELECTRICAL CONNECTION: 1-3/8" DIA. HOLE
FOR 1" TRADE SIZE CONDUIT; 31-3/4" AFF.
P1 SINGLE FILL AND RINSE CONNECTION:
3/4" FEMALE GARDEN HOSE FITTING ON 6' LONG
HOSE SUPPLIED WITH MACHINE; 140°F WATER
MIN. FOR LXiC, 110°F WATER MIN. FOR LXiH,
1-1/2" AFF.
P2 DRAIN CONNECTION: 3/4" MPT FITTING WITH
6' LONG HOSE SUPPLIED WITH MACHINE;
3-9/16" AFF.
WARNING:
REQUIRED FLOWING WATER PRESSURE TO THE DISHMACHINE IS
20 ± 5 PSIG. IF PRESSURES HIGHER THAN 25 PSIG ARE PRESENT, A
PRESSURE REGULATING VALVE MUST BE INSTALLED IN THE WATER
LINE TO THE DISHMACHINE (BY OTHERS).
IMPORTANT: THE SODIUM HYPOCHLORITE (LIQUID BLEACH) CON-
TAINER SHOULD BE PLACED NO HIGHER THAN 10" ABOVE FLOOR.
IF BLEACH CONTAINER IS TO BE PLACED IN CABINET ADJACENT
TO MACHINE, A 1/2" DIA. HOLE IS REQUIRED IN THE CABINET TO
RUN BLEACH SUPPLY LINE.
USE ONLY 6% SODIUM HYPOCHLORITE (LIQUID BLEACH) AS
SANITIZING CHEMICAL TO INSURE PROPER OPERATION OF DISH-
MACHINE. IF 8.4% IS TO BE UTILIZED CONTACT HOBART SERVICE
TO CHANGE THE SANITIZER PUMP SETTINGS.
DO NOT PRE-MIX RINSE AGENT AND SODIUM HYPOCHLORITE
(LIQUID BLEACH).
CERTAIN MATERIALS INCLUDING SILVER PLATE, ALUMINUM AND
PEWTER ARE ATTACKED BY SODIUM HYPOCHLORITE (LIQUID
BLEACH). SEE INSTRUCTIONAL MANUAL.
STEAM GENERATED FROM NORMAL OPERATION MAY ESCAPE FROM
THE DOOR. WOOD LAMINATE, VENEERS, ETC. ARE UNSUITABLE
MATERIALS FOR USE IN AREAS EXPOSED TO DISHWASHER STEAM
AND DETERGENTS. STAINLESS STEEL OR OTHER MOISTURE-
RESISTANT SHIELDS ARE RECOMMENDED FOR SURFACES ADJACENT
TO LXi SIDES AND TOP.
NOTES:
1. ALL VERTICAL MACHINE DIMENSIONS TAKEN FROM FLOOR MAY
BE INCREASED BY 1".
2. MOIST AIR ESCAPES FROM THE DOOR.
USE ONLY MOISTURE RESISTANT MATERIALS ADJACENT TO LX
i
SIDES AND TOP.
3. A VENT HOOD IS NOT RECOMMENDED ABOVE THE LX
i UN-
DERCOUNTER DISHWASHER SINCE IT DOES NOT PRODUCE
EXCESSIVE VAPORS
PLUMBING NOTES:
1. WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD
OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN COMMON
WATER SUPPLY LINE AT SERVICE CONNECTION.
2. RECOMMENDED WATER HARDNESS TO BE 4-6 GRAINS FOR
BEST RESULTS.
3. MINIMUM WATER CONDUCTIVITY REQUIRED - 30 MICRO-
MHOS/CM.
4. IF DRAIN HOSE IS LOOPED ABOVE A SINK, THE LOOP MUST NOT
EXCEED 38" AFF.
MACHINE TYPE &
SPECIFICATION
RATED
AMPS
MIN SUPPLY
CKT CONDUCT
AMPACITY
MAX
PROTECTIVE
DEVICES
LXiC (120/60/1)
USE 90°C STRANDED
COPPER WIRE ONLY.
15.4 20 20
LXiC (120/208-240(3W)/60/1*)
LXiC (208-240/60/1)
USE 90°C STRANDED
COPPER WIRE ONLY.
13.6 20 20
LXiH (120/208-240(3W)/60/1*)
LXiH (208-240/60/1)
USE 90°C STRANDED
COPPER WIRE ONLY.
37.7 50 50
ELECTRICAL OPTIONS BELOW ARE NON STANDARD VOLTAGES AVAILABLE
AT EXTRA COST. CONSULT FACTORY FOR PRICING AND LEAD TIME.
LXiH 208-240/60/3
480/60/3
220-240/50/1
380-400/60/3
29.5
14.8
38.1
17.1
35
20
50
25
35
20
50
25