Hobart ML-124067 Freezer User Manual


 
– 12 –
BY TIME
TYPE: SOFT CHILL
CYCLE TIME: 01:30
MAIN START
BY TIME
TYPE: FREEZE
CYCLE TIME: 01:30
MAIN START
MAIN MENU
BY TIME
Timer counts down until cycle is done.
From the Main Menu, select BY TIME.
Select the Type: CHILL, SOFT CHILL or FREEZE*.
SEIRESPMETYBGNITTESEMITLAITINIEGNAREMIT
FCQH,CQHLLIHC03:1000:42OT10:00
FCQH,CQHLLIHCTFOS03:1000:42OT10:00
FCQHEZEERF03:1000:42OT10:00
To adjust the CYCLE TIME: Press or .
To begin Chilling, select START.
(MAIN returns to the Main Menu.)
Close the door.
Probes display temperatures but have no effect on the
chilling process.
Select STOP / RESET to obtain these menu items:
°
ADD 30 MINUTES adds 30 minutes to the timer.
°
RESET TIMER re-starts at the original time setting.
°
CONTINUE resumes the cycle at the time remaining.
°
STOP allows a report to be printed and then returns
to Main Menu.
Time Remaining displays in the lower left corner —
Hr: Min: Sec.
The timer has counted down to 0:00:00. The chiller
changes to HOLDING Mode.
Press MUTE to silence buzzer.
* Some chill types are not available on all models.
BY TIME
TYPE: CHILL
CYCLE TIME: 01:30
MAIN START
DOOR OPEN AIR: 14°F
1 159
°F 156°F 3
2 154°F
1:30:00 STOP/RESET
CHILLING AIR: 14°F
1 159
°F 156°F 3
2 154°F
1:29:57 STOP/RESET
HOLDING AIR: 14°F
1 39°F 42°F 3
2 44°F
0:00:00 MUTE
MAIN MENU 08:05:01
BY TEMP BY PROD
BY TIME
MORE
MAIN MENU 08:06:01
HOLD PROD PRINT
DEFROST SETUP
BACK
BY TIME
ADD 30 MINUTES
RESET TIMER
STOP CONTINUE