Honeywell 50045947-001 Water Dispenser User Manual


 
4
FIG. 2
RO SYSTEM ASSEMBLY INSTALLATION
1. Choose a location for the RO system
assembly capable of holding up to 7 lbs.
2. Mark screw/washer location 9 inches apart.
3. Fasten screws and hanger washers.
Sheet metal install – use sheet metal
screws (not provided).
Wood stud install – use provided wood
screws and hanger washers.
4. Hang the RO system assembly on the
hanger washers.
5. Connect Filter Assembly top cover.
6. Connect three filter cartridges in the order
below by turning cartridge to the right,
ensuring thread is properly engaged and
seal is tight.
Align #3 staging tank with RO system
assembly connection #3.
Align #2 RO filter with RO system
assembly connection #2.
Align #1 sediment filter with RO system
assembly connection #1.
7. Move water storage tank into place on the
floor surface. Use the included tank stand
and position the tank upright or on its side
(Models 50045947-001 & 50045947-002).
8. Apply PTFE thread seal (Teflon) tape on
the storage tank thread and install the shut-
off valve (Models 50045947-001 &
50045947-002).
9”
NOTE: Be sure to allow a minimum space
of 1-1/2" under the system for removing
and replacing the filters.
Shutoff
Valve
Storage
Tank
Hanger
Washer
(2)
Screw
(2)
Top Cover
#3
Staging Tank
#2
RO Filter
#1
Sediment Filter
(level)