Honeywell UC100 Oven Accessories User Manual


 
UC100 ULTRAVIOLET SYSTEM REPLACEMENT BULB/HANDLE ASSEMBLY
69-1444—5 2
MERCURY NOTICE
This device contains mercury in the sealed ultraviolet
bulb(s). Do not place your used bulb(s) in the trash.
Dispose of properly.
Broken Bulb Cleanup.
Do not use a household vacuum.
Sweep debris (phosphor/glass) into a plastic bag and
dispose of properly.
Contact your local waste management authority for
instructions regarding recycling and the proper
disposal of old bulb(s).
Replacing Your Bulbs
SmartLamp™ Models (UV100E1043, UV100E2009,
and UV100E3007)
Replacement of your bulbs is required when LED on front of
unit is lighted solidly.
NOTE: LED blinking slowly, one second on and one second
off, indicates that ten percent or less of bulb life
remains and homeowner must order new bulb(s).
IMPORTANT
Remember to press the reset button for five seconds
after replacing the bulb(s).
UV100A1000, UV100A1018, UV100A1026,
UV100A1059, UV100A2008, UV100E1001,
UV100E1019, UV100E1027, UV100E1035 Models
Annual replacement of your bulbs is required.
To replace your bulbs:
1. Select and obtain the correct replacement bulb for your
unit. See Table 1.
2. Disconnect the power to your heating and cooling
system.
3. Unplug or turn off power to your UV System and allow
the bulbs to cool for at least 15 minutes.
4. Rotate the lamp handle counterclockwise and gently
pull the lamp handle to remove the bulb. See Fig. 1.
IMPORTANT
If the bulb in your model has external wires running
along the glass surface, be sure to avoid pulling on
those wires.
Fig. 1. Remove lamp bulb.
5. If you have a SnapLamp™ handle, follow steps 5 and 6;
otherwise, proceed to step 7. Grasp the SnapLamp™
handle in one hand and the bulb glass in the other and
pull straight apart. See Fig. 2.
Fig. 2. Disconnect bulb from SnapLamp™ handle.
6. Insert the new bulb into the SnapLamp™ handle by
aligning the notch and pushing straight together.
See Fig. 3.
Fig. 3. Replace bulb in SnapLamp™ handle.
7. Insert the lamp handle into the base with the lamp light
indicator at the eleven o’clock position. Continue
pushing and gently rotating counterclockwise until the
lamp inserts fully into the base. See Fig. 4.
M22841
M22851
M22853