![](http://pdfasset.owneriq.net/b/17/b17277c0-8488-4936-ac22-3d4e1e995c7b/b17277c0-8488-4936-ac22-3d4e1e995c7b-bg20.png)
32
8) Remove the discharge hose restriction and allow the water to be pumped out normally.
Power to the appliance will be restored when the water in the drain pump returns to a
normal level.
9) If the appliance fails to turn off with the discharge hose restricted or the drain pump fails
to pump out the water, replace the drain pump.
Fig. 2
Discharge Hose