Hoshizaki F-1000MAF/-C Ice Maker User Manual


 
46
F-1000MWF-C
APPROXIMATE Ambient Water Temp. (F)
ICE PRODUCTION Temp. (F)
PER 24 HR. 70 790 (358) 760 (346) 750 (340)
80 735 (333) 720 (327) 710 (322)
90 695 (316) 685 (311) 670 (304)
lbs./day (kg/day) 100 660 (299) 645 (294) 600 (272)
APPROXIMATE ELECTRIC 70 1160 -- 1170 -- 1185 --
CONSUMPTION 80 1160 -- 1170 -- 1185 --
90 1160 -- 1170 -- 1185 --
watts 100 1160 -- 1170 -- 1185 --
APPROXIMATE WATER 70 398 (1.81) 534 (2.43) 859 (3.91)
CONSUMPTION PER 24 HR. 80 414 (1.88) 554 (2.52) 898 (4.08)
(TOTAL) 90 427 (1.94) 574 (2.61) 939 (4.27)
gal./day (l/day)
100 442 (2.01) 598 (2.72) 1032 (4.69)
EVAPORATOR OUTLET TEMP. 70 23 (-5) 23 (-5) 25 (-4)
80 23 (-5) 23 (-5) 25 (-4)
90 23 (-5) 23 (-5) 25 (-4)
°F (°C) 100 23 (-5) 23 (-5) 25 (-4)
HEAD PRESSURE 70 263 (18.5) 266 (18.7) 269 (18.9)
80 263 (18.5) 266 (18.7) 269 (18.9)
90 263 (18.5) 266 (18.7) 269 (18.9)
PSIG (kg/cm²G)
100 263 (18.5) 266 (18.7) 269 (18.9)
SUCTION PRESSURE 70 33 (2.3) 34 (2.4) 35 (2.5)
80 33 (2.3) 34 (2.4) 35 (2.5)
90 33 (2.3) 34 (2.4) 35 (2.5)
PSIG ( kg/cm²G )
100 33 (2.3) 34 (2.4) 35 (2.5)
WATER FLOW FOR CONDENSER 40 gal/h (AT 90°F /WT 70°F)
PRESSURE DROP OF COOLING WATER LINE Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER 7110 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR 1340 BTU/h (AT 90°F /WT 70°F)
Note: The data without *marks should be used for reference.
50 70 90
We reserve the right to make changes in specifications and design without prior notice.