19
2nd Cycle and after with pump drain
IMPORTANT
Freeze cycle time is limited to 60 minutes even if
Float Switch does not open.
1. Float Switch opens and signals to complete
freeze cycle.
Drain Timer starts counting.
2. Drain Timer stops counting.
Pump drain is completed.
IMPORTANT
Water Valve opening is
limited to 6 minutes.
3. Thermistor reads 48°F.
Defrost Timer starts
counting.
4. Defrost Timer stops counting.
Defrost cycle is completed and freeze cycle
starts.
IMPORTANT
1. Board never accepts defrost completion signal
within the first 2 minutes in defrost cycle.
2. Defrost cycle time is limited to 20 minutes even if
Defrost Timer does not stop counting.
5. After the first 5 minutes in freeze cycle.
Ready to complete freeze cycle when Float
Switch circuit opens.
IMPORTANT
Board never accepts freeze completion signal
within the first 5 minutes in freeze cycle.