Hoshizaki KM-255BWH Ice Maker User Manual


 
9
C. Location
WARNING
This icemaker is not intended for outdoor use. Normal operating ambient
temperature should be within +45°F to +100°F (+7°C to +38°C); Normal
operating water temperature should be within +45°F to +90°F (+7°C to +32°C).
Operation of the icemaker, for extended periods, outside of these normal
temperature ranges may affect production capacity.
For best operating results:
• Icemaker should not be located next to ovens, grills or other high heat producing
equipment.
• Level the icemaker from side-to-side and front-to-rear by adjusting the legs. Location
should provide a firm and level foundation for the equipment.
• Allow 6" (15 cm) clearance at the rear and top for ease of maintenance and/or service
should they be required.
D. Electrical Connection
CAUTION
The GREEN ground wire in the factory-installed power cord is connected
to a screw on the bracket where the cord enters the machine. If it becomes
necessary to remove or replace the power cord, be sure to connect the power
cord's ground wire to this screw upon reattachment.
• This icemaker must have a separate power supply or receptacle of proper capacity. See
the nameplate.
• Usually an electrical permit and services of a licensed electrician are required.