1) Secure the legs to the remote condenser unit with eight M8×16 mm hexagon bolts and
M8 nuts as shown in the illustration. See Fig. 5.
) The legs have eight mounting holes. Secure the legs with eight bolts (not included).
Fig. 5
Hexagon Bolt
with Split Lock
Washer and
Flat Washer
M8
Hexagon Nut
4. Line Set
• Precharged tubing kits, available as optional equipment from HOSHIZAKI AMERICA, are
recommended. Field fabricated line sets are allowed, see instructions below.
• The maximum line length for the standard refrigerant charge is 66 feet. Should an
installation require a longer line length, additional refrigerant must be added to the
system. Add .4 oz. of R-404A for each foot over 66 feet to a maximum of 100 feet or call
1-800-33-1940 for recommendations.
Note: If the recommended guidelines of the installation are exceeded, the icemaker
performance may be reduced.
• The maximum vertical distance between the remote condenser unit and the icemaker is
33 feet above or 10 feet below the icemaker. These distances are measured tting to
tting.
CAUTION
Failure to install the equipment within these guidelines may adversely affect
performance, component life, and warranty coverage.