Hoshizaki KML "H" SERIES Ice Maker User Manual


 
103
15. REMOVAL AND REPLACEMENT OF SPRAY TUBES
1) Turn off the power supply.
2) Remove the Front Panel and the Insulation Panel.
3) Remove the Rubber Hoses from the Spray Tubes (Water Supply Pipe).
4) Release the Clamps, and disconnect the Rubber Hoses.
5) Remove the Spray Tubes by squeezing the side tabs.
6) Install the new Spray Tubes, and replace the removed parts in the reverse order of
which they were removed.
7) Replace the panels in their correct positions.
8) Turn on the power supply.
14. REMOVAL AND REPLACEMENT OF PUMP MOTOR
1) Turn off the power supply.
2) Remove the Front Panel.
3) Remove the three screws and the Float Switch Assembly.
4) Remove the wiring connectors from the Pump Motor leads.
5) Remove the four screws and the Pump Motor.
5) Install the new Pump, and replace the removed parts in the reverse order of which
they were removed.
6) Turn on the power supply, and check for leaks.
7) Replace the Front Panel in its correct position.