14. KM-1601SRH with URC-21F Auxiliary Codes: some S-1 and S-2 and Later
This data applies to units with a 15 l/min or 11 l/min water valve. The 15 l/min water
valve is part number 3U0111-01 and has J248-030 stamped on the side of the valve
facing the rear of the unit. The 11 l/min water valve is either part number 4A1176-04
or 4A5251-04 and has the part number stamped on the side of the valve facing the
front of the unit.
SPECIFICATION SHEET
AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V)
AMPERAGE 12.8 A (5 Min. Freeze AT 104°F/WT 80°F)
MINIMUM CIRCUIT AMPACITY 20 A
MAXIMUM FUSE SIZE 20 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 2700(4.30) 2610(4.00)
WATER gal./24HR (gal./100 lbs.) 375(24.9) 785(50.2)
ICE PRODUCTION PER CYCLE 31.2 lbs. (14.2 kg) 1440 pcs.
TOTAL REFRIGERANT CHARGE R404A, 24 lb. 14.6 oz. (11300g)
REFRIGERANT CHARGE BY UNIT (Icemaker 15 lb. 3.4 oz. Cond. Unit 9 lb. 11.2 oz.)
PERFORMANCE DATA SHEET
70/21 1564 709
1547 702 1468 666
80/27 1551 703 1524 691 1415 642
90/32 1547 702 1505 683 1407 638
lbs./day kg./day 100/38 1512 686 1482 672 1317 597
70/21
80/27
90/32
watts 100/38
70/21 785 2.97
665 2.52 583 2.21
80/27 694 2.63 507 1.92 471 1.78
90/32 665 2.52 375 1.42 318 1.20
gal./day m3/day 100/38 519 1.97 361 1.37 266 1.01
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 213 15.0
226 15.9 245 17.2
80/27 223 15.7 243 17.1 263 18.5
90/32 226 15.9 257 18.1 277 19.5
PSIG kg/cm2G 100/38 230 16.2 262 18.4 296 20.8
70/21 40 2.8 41 2.9 44 3.1
80/27 41 2.9 43 3.1 47 3.3
90/32 41 2.9 45 3.2 48 3.4
PSIG kg/cm2G 100/38 42 3.0 46 3.2 51 3.6
CONDENSER VOLUME 441 CU. IN (URC-21F)
APPROXIMATE ICE
PRODUCTION PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10 70/21 90/32
APPROXIMATE ELECTRIC
CONSUMPTION
2610 2636 2684
2630 2671 2725
2636 2700 2752
2650 2712 2800
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
24 25 27
25 27 29
25 28 30
26 29 32
HARVEST CYCLE TIME
5.6 4.6 4.2
4.8 3.4 3.4
4.6 2.4 2.2
TOTAL HEAT OF REJECTION FROM COMPRESSOR 3,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
3.6 2.3 2.0
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER 22,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
ENG.F-011.1.0205