Hotpoint BS43K/1 Oven User Manual


 
3
GB
Electrical Connection
Electrical connection
The electrical connection to the mains must be made
on the appliance. The power voltage and frequency
are as indicated on the rating plate.
! THIS APPLIANCE MUST BE EARTHED.
Connecting the power supply cable
To open the terminal board:
Using a screwdriver, press on the tabs situated on
each side of the terminal board cover.
Pull open the terminal board cover.
To connect the power supply cable, proceed as
follows:
Unscrew the cable clamp screw and the contact
screws L-N-$.
Fasten the wires beneath the screwheads using the
following colour scheme: Blue (N) Brown (L)
Yellow-Green $
Fasten the power supply cable in the
corresponding cable clamp and close the cover.
Electrical Connection:
Voltage Frequency: 230
V-1+N 50Hz
Fuse Section: 16A
Supply cable: 3x1.5mm
2
You can connect your oven to the system means of a
terminal board. Refer to above information for the
minimal cable sections and the calibration of the
protective elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker - with a minimum contact
opening of 3mm - should be installed between the
appliance and the mains.
Power cable supply connection to the electrical
mains:
We recommend you use a power supply cable which
is long enough to allow you to take the oven out of its
recess in the event of maintenance operations (only
use HAR - H 05 - RRF quality cables fitted with a plug
conforming to the regulations in force.
The plug must be accessible at all times.
Unplug the appliance before all operations, even
when replacing the oven lamp.
Using the appliance without correct earthing is
highly dangerous.
! After connecting
the appliance to the flexible
cable, tighten all the screws on the terminal board.
42
NL
DATA PLATE
Dimensions
width cm 43.5
height cm 32
depth cm 40
Volume
lt. 56
Electrical
connections
voltage: 230-240V ~ 50Hz
maximum power absorbed
2250W-2400W
Directive 2002/40/EC on the label
of electric ovens.
Standard EN 50304
ENERGY LABEL
Declared energy consumption for
Forced convection Class – heating
mode: Fan assisted
This appliance conforms to the
following European Economic
Community directives:
- 2006/95/EEC of 12/12/06 (Low
Voltage) and subsequent
amendments;
- 89/336/EEC of 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments;
- 93/68/EEC of 22/07/93 and
subsequent amendments.
- 2002/96/EC