8
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
INSTALLATION INSTRUCTIONS
TECHNICAL DATA
Gas connection Rp ½ (½" BSP female)
Pressure test point Front left hotplate injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection 4mm
2
twin and earth
230/240V a.c. 50Hz.
CH60DTXF S S CH60DTCF S
Professional 60
G20 at 20mbar
G30 at 28-30mbar
G31 at 37mbar
BURNER
HEAT INPUT INJECTOR HEAT INPUT INJECTOR
HOTPLATE
Front Left
4.1 kW 100+72+100 3.8 kW (275g/h) 63+42+63
HOTPLATE
Rear Right
3.05 kW 116 3.0 kW (220g/h) 86
HOTPLATE
Front Right and Rear Left
2.0 kW 103 2.0 kW (145g/h) 70
TOTAL LOAD 4.5 / 4.9 kW
Traditional 60
G20 at 20mbar
G30 at 28-30mbar
G31 at 37mbar
BURNER
HEAT INPUT INJECTOR HEAT INPUT INJECTOR
HOTPLATE
Front Left and Rear Right
3.05 kW 116 3.0 kW (220g/h) 86
HOTPLATE
Front Right and Rear Left
2.0 kW 103 2.0 kW (145g/h) 70
TOTAL LOAD 4.5 / 4.9 kW
CH60DPCF S CH60DPXF S