Installation
Electrical Requirements
For your own safety, we recommend that your cooker
is installed by a competent person such as one who is
registered with NICEIC (National Inspection Council for
Electrical Installation Contracting). The cooker should
be installed in accordance with the latest edition of the
IEE Regulations.
Warning: This appliance must be earthed.
Electrical Connections
The installer must check that the voltage shown on
the rating plate corresponds with the house electricity
supply. The cooker must be supplied via a suitable
double pole isolating switch, having a contact
separation of at least 3mm in all poles placed in a
readily accessible position adjacent to the cooker. If
the cooker is to be wired into a connector unit, this
may be positioned behind the cooker providing the
following requirements are met:
i) The connector unit must not project from the wall
more than 25mm.
ii) The top of the connector must not be more than
130mm above floor level.
Remove the terminal cover at the rear base of the
cooker. Pass the cable through the cable clamp and
connect to the appropriate terminals provided.
Allow sufficient cable for any future servicing.
Tighten the screws on the cable clamp and replace the
cover. Make main connections in the connector unit or
cooker control unit. This appliance conforms to B.S. EN
55014 regarding suppression of Radio and Television
reception interference.
A double Pole control switch having a minimum rating
of 32 amps should be used to feed the cooker using
a suitably rated cable. Where a hob is fitted adjacent
to or over the cooker, a 45 amp Double Pole control
switch should be used to feed both units via separate
suitably rated cables.
We recommend a minimum of 4mm2 PVC insulated
twin and earth cable conforming to B.S. 6004 for
connection of each appliance.
In all cases adhere to routing details (see fig. 4).
This appliance must not be installed over any other
appliance that generates heat such as a plinth heater.
Note: Due to many different types of installation, a
mains cable is not supplied with this product. The
installer will fit the correct type and length of cable.
Important
It is essential that the lower cupboard is constructed
in the manner illustrated i.e. having side, back, and
roof panels so joined as to provide no apertures which
could permit access to the oven unit when installed.
1. General
The appliance is designed for mounting at a safe level
into an oven housing which must be secured to the
backing wall.
2. Ventilation
a. The oven housing unit cabinet dimensions must
comply with fig. 4.
b. An air gap of 50mm minimum must be provided at
the rear of any top or bottom cupboards or shelves
(see fig. 1).
c. It is necessary that the cabinets are provided with
unobstructed ventilation, i.e. from adjacent cabine-
try. This can be done by either raising the base of
the cabinets using the adjusting feet (or spacers)
or alternatively by providing a slot in the cabinet
plinth to the dimensions in fig. 1.
d. The air gap at rear allows the warmed air to pass out
of the inner cabinet space. Where it is intended to fit
cupboards above the oven unit to ceiling height, it is
essential that the warmed air is exhausted through
the front of the cabinet (see fig. 1).
e. If an oven unit is installed adjacent to a tall cabinet,
steam escaping from the oven when the door is
opened could condense on and maybe stain the
adjacent surface. To prevent permanent staining,
the adjacent surface should be made of a material
that is heat resisting and easy to clean. Adjacent
tall cabinets should not be deeper than the oven
housing cabinet.
3. Final Installation
a. Using a spirit level, check that the housing cabinet
is level from side to side and from front to back in
its installed position.
b. Correct any unevenness by placing spacers under
the bottom of the cabinet. Make sure that the cabi-
net rests firmly on the floor without rocking.
c. Before the oven is fitted, the cabinet must be firmly
secured to the backing wall for stability.
d. The oven unit should now be lifted (this is a two
person lift) into the cabinet and pushed fully home.
e. Finally, the oven is secured to the cabinet by means
of the four Phillips C/SK Head screws - two through
each side trim.
f. Remove all packaging material from the grill and
oven interior.
List of loose items: