Electrical Connection
Electrical Connection
If your appliance is supplied with a
13 amp. fused plug it can be
plugged into a 13 amp socket for
immediate use. Before using the
appliance please read the
instruction below.
Replacing the fuse:
When replacing a faulty fuse, a 13
amp ASTA approved fuse to BS
1362 should always be used, and
the fuse cover re-fitted. If the fuse
cover is lost, the plug must not be
used until a replacement is
obtained.
Replacement fuse covers:
If a replacement fuse cover is
fitted, it must be of the correct
colours as indicated by the
coloured marking or the colour that
is embossed in words on the base
of the plug. Replacements can be
obtained directly from your nearest
Service Depot.
Removing the plug:
If your appliance has a non-
rewireable moulded plug and you
should wish to remove it to re-route
the mains cable through partitions,
units etc., please esure that either:
- the plug is replaced by a fused 13
amp re-wireable plug bearing the
BSI mark of approval
- or:
- the mains cable is wired directly
into a 13 amp cable outlet,
controlled by a switch, (in
compliance with BS 5733) which
is accessible without moving the
appliance.
Disposing of the plug:
Ensure that before disposing of the
plug itself, you make the pins
unusable so that it cannot be
accidentally inserted into a socket.
Instruction for connecting
cable to an altenative plug:
Important: the wires in the mains
lead are coloured in accordance
with the following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the wires in the
mains lead may not correspond
with the coloured markings
identifying the terminal in your plug,
proceed as follows:
connect Green & Yellow wire to
terminal marked E or
coloured
Green or Green & Yellow.
Connect Brown wire to terminal
marked L or coloured Red.
Connect Blue wire to terminal
marked N or coloured Black.
If a 13 amp plug (BS 1363) is used
it must be fitted with a 13 amp fuse.
A 15 amp plug must be protected
by a 15 amp fuse, either in the plug
or adaptor or at the distribution
board.
If you are in any doubt about the
electrical supply to your machine,
consult a qualified electrician
before use.
How to connect an alterna-
tive plug:
The wires in this mains lead are
coloured in accordance with the
following code:
- Blue NEUTRAL (N)
- Brown LIVE (L)
- Green
and Yellow EARTH (E)
Disposing of the appliance:
When disposing of the appliance
please remove the plug by cutting
the mains cable as close as possible
to the plug body and dispose of it
as described above.
Caution:
The dishwasher
plug must be
accessible even
when the appliance
is installed as a
built-in unit so that
maintenance can
be done safely.
GREEN &
YELLOW
BROWN
BLUE
13 amp fuse
CROSS-BAR
CORD GRIP
Warning:
this appliance
must be earthed.
The following
operations should
be carried out by a
qualified
electrician.