9
Installation - Model E600
These instructions are intended for the qualified technician
installing the appliance in order to insure that the installation,
adjustments and maintenance procedures are performed
correctly and comply with the regulations currently in effect.
Important: the hob must be disconnected from the
power supply before making any adjustments or
performing any maintenance, etc.
Installing built-in hobs
The hob has a type X protection rating against overheating
in compliance with regulation CEI 335-2-6. Therefore, the
hob cannot be installed alongside of cabinets which are
higher than the surface of the hob itself. The following
precautionary measures should be observed in order to
ensure proper installation:
a) Hoods must be installed in compliance with the required
specifications contained in the instruction manual for
the hood itself.
b) The built-in ceramic glass top can be installed on any
counter top as long as it is 600 mm or more in width
and resistant to temperatures of up to 100°C.
The dimensions and the position of the hole are shown
in fig..
575
mm.
505
mm.
39
mm.
560
mm.
+0 -2
490
mm.
+0 -2
48
mm.
X (CEI 335-2-6)
These measurements must absolutely be observed in
so far as improper installation can cause the surrounding
surface areas to overheat. It is recommended that the
hob be installed at a distance of at least 40 mm from
the back wall or other vertical surfaces to ensure that
the air circulates properly over the cooking area and to
avoid overheating the surrounding surfaces. A seal or
gasket is provided with the hob; make sure that it
adheres properly to the bottom part of the frame of the
hob.
The seal must fit properly around the entire hob frame
and especially along the corners in order to create a
seal between the counter top and the cooktop itself so
as to prevent spills or splashes from leaking into the
cabinet below. Fasten the 4 hooks supplied into the
slots as shown in Fig.;
Fastening diagram for the hooks
A
A
A
A
30
40
Fastening positions Hook placement for
40 and 30 mm tops
Insert the hob into the hole, pressing firmly around the
frame to make it adhere to the counter top.
Important: The surface where the hob is installed must
be perfectly flat. Deformations caused by improper
installation may affect the characteristics of the hob,
and, therefore, its performance.
c) If a wooden panel is installed beneath the hob for
insulation purposes, it must be positioned at least 20
mm from the bottom part of the hob itself.
Note: If the hob is installed above a built-in oven, it is
preferable that the oven be installed in such a way that it
is set on two strips of wood; if, on the other hand, the oven
is installed on a continuous base, there must be an opening
in the back of at least 45 x 560 mm.
560 mm.
45 mm.
If the hob is installed above a built-in oven equipped with a
forced air cooling system, air intake and exhaust slots
must be provided to ensure that the air circulates properly
within the cabinet. Figures provide illustration of possible
installation solutions.