TECHNICAL DATA
DIMENSIONS
Height 900 - 915mm
Width 600mm
Depth 595mm (excluding door handles)
GENERAL
Gas connection Rp
1
/
2
(
1
/
2
” BSP female)
Gas Supply Natural gas G20 at 20 mbar. Can be converted
(with a service kit) for propane G31 at 37mbar and
butane G30 at 28-30mbar
Pressure test point Front left hotplate burner injector.
Gas rate adjustment None
Aeration adjustment None
Electrical connection 4mm
2
twin and earth.
230-240V a.c. 50Hz.
Total heat input Gas Natural gas 9.8kW
LPG 9.6kW (700g/hr)
Total heat input (Electric) 4.74 - 5.16kW
27
INSTALLATION INSTRUCTIONS
Butane (G30) or Propane (G31)Natural Gas (G20)
Heat input
Heat input Gas rate
injector
Injector
Electrical
Heat input
Burner
Front left and
rear right
hotplates
Front right
and rear left
hotplates
Grill 2.66kW
3.0kW
1.8kW
134
109
1.8kW
130g/hr
3.0kW
220g/hr
90
72
1.86kW
2.50kW
Top Oven
Main Oven