Hotpoint EG72 Oven User Manual


 
TECHNICAL DATA
DIMENSIONS
Height 900 - 915mm
Width 600mm
Depth 595mm (excluding door handles)
GENERAL
Gas connection Rp
1
/
2
(
1
/
2
”BSP female)
Pressure test point Hotplate burner injector.
Gas rate adjustment None
Aeration adjustment None
Electrical connection 4mm
2
twin and earth.
230-240V a.c.50Hz.
25
INSTALLATION INSTRUCTIONS
HOTPLATE
Front left and rear right
3.0kW (220g/h)
HOTPLATE
Front right and rear left
1.8kW (130g/h)
GRILL 2.4 / 2.6kW
TOP OVEN 1.7 / 1.85kW
MAIN OVEN 2.3 / 2.5kW