Hotpoint HD 6 Ventilation Hood User Manual


 
8
GB
General
Carefully read the following important information regard-
ing installation safety and maintenance.
Keep this information booklet accessible for further con-
sultations.
The appliance has been designed for use in the ducting
version (air exhaust to the outside – Fig.1B), fi ltering ver-
sion (air circulation on the inside – Fig.1A).
Safety precaution
1. Take care when the cooker hood is operating simul-
taneously with an open fi replace or burner that depend
on the air in the environment and are supplied by other
than electrical energy, as the cooker hood removes the
air from the environment which a burner or fi replace need
for combustion.
The negative pressure in the environment must not exceed
4Pa (4x10-5 bar).
Provide adequate ventilation in the environment for a
safe operation of the cooker hood. Follow the local laws
applicable for external air evacuation.
Before connecting the model to the electricity net-
work:
- control the data plate (positioned inside the appliance)
to ascertain that the voltage and power correspond to
the network and the socket is suitable. If in doubt ask a
qualifi ed electrician gure 1C.
- If the power supply cable is damaged, it must be replaced
with another cable or a special assembly, which may be
obtained direct from the manufacturer or from the Techni-
cal Assistance Centre.
- This device must be connected to the supply network
through either a plug fused 3A or hardwired to a 2 fase
spur protected by 3A fuse.
2. Warning!
In certain circumstances electrical appliances may
be a danger hazard.
A) Do not check the status of the fi lters while the
cooker hood is operating
B) Do not touch bulbs or adjacent areas, during
or straight after prolonged use of the lighting
installation.
C) Flambè cooking is prohibited underneath the
cooker hood
D) Avoid free fl ame, as it is damaging for the fi lters
and a fi re hazard
E) Constantly check food frying to avoid that the
overheated oil may become a fi re hazard
F) Disconnect the electrical plug prior to any mainte-
nance.
G) This appliance is not intended for use by young
children or infi rm persons without supervision
H) Young children should be supervised to ensure
they do not play with the appliance
I) There shall be adequate ventilation of the room
when the rangehood is used at the same time as ap-
pliances burning gas or other fuels
L) There is a risk of fi re if cleaning is not carried out
in accordance with the instructions
This appliance conforms to the European Directive
EC/2002/96, Waste Electrical and Electronic Equipment
(WEEE). By making sure that this appliance is disposed
of in a suitable manner, the user is helping to prevent
potential damage to the environment or to public health.
The
symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to
a suitable electric and electronic appliance recycling
collection point. Follow local guidelines when disposing
of waste.
For more information on the treatment, re-use and
recycling of this product, please contact your local
authority, domestic waste collection service or the shop
where the appliance was purchased.
Installation instructions
Assembly and electrical connections must be carried out
by specialised personnel.
• Electric Connection
The appliance has been manufactured as a class II,
therefore no earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load indi-
cated on the description label. Where a plug is provided,
the cooker hood must be installed in order that the plug
is easily accessible. An omnipolar switch with a minimum
opening of 3mm between contacts, in line with the electri-
cal load and local standards, must be placed between the
appliance and the network in the case of direct connection
to the electrical network.
The minimum distance between the support surfaces
of the cooking pots on the cooker top and the lowest part
of the cooker hood must be at least 65 cm. If a connec-
tion tube composed of two parts is used, the upper part
must be placed outside the lower part. Do not connect
the cooker hood exhaust to the same conductor used to
circulate hot air or for evacuating fumes from other appli-
ances generated by other than an electrical source. Before
proceeding with the assembly operations, remove the anti-
General