Hotpoint HDF6.5SAB Ventilation Hood User Manual


 
GB
9
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
Installation
Theinstallationprocedureisillustratedintherstpages
of this manual.
Theinstallationmustbedonebyaqualiedtechnician.
Electrical hook up
The mains voltage must match that given on the ratings
label inside the hood itself. If the hood has a power plug,
connect the hood to an easily accessible regulatory power
socket. If it does not (direct connection to the mains), or the
socket is not easily accessible, install a two-pole regulatory
switch to enable total disconnection from the mains in case
of category III overvoltage, as required by the installation
regulations.
Caution! Always check that the mains cable is hooked
up properly and check that it operates correctly before
reconnecting the hood to the mains.
Air exhaust (for ducted units)
Connectthehoodtoaductandwallexhaustholeofa
diameterequaltothatoftheairoutletange.Usingasmaller
diameter tube and exhaust hole reduces the extraction
capacity of the hood and also increases its running noise.
The manufacturer is not liable for any consequences of
doing so.
!Usetheshortestductrequiredtoachievethepurpose.
!Useaductwithasfewbendsaspossible
! Avoid suddenly changing the diameter of the duct.
! The duct must have as smooth an inner surface as
possible.
! The duct must be made of regulatory material.
!Donotconnectthehoodtouescarryingcombustion
fumes from other equipment (boilers, GLASSs, stoves, etc.).
! Observe the instructions of the competent authorities in
relation to the air exhaust. The air being exhausted may not
be exhausted into a wall cavity unless the cavity in question
isspecicallyintendedforthispurpose.
!Equiptheroomwithairintakestopreventthehoodcreating
suction pressure in the interior (this must not exceed 0.04
mbar).
! The manufacturer is not liable for any consequences of
failure to observe these instructions.
Filter or ducted?
! Your hood is supplied as a ducted unit.
Ifyouwishtouseitasalterunit,youmustinstalltheproper
ACCESSORYKIT.
Note: If supplied with the hood, the accessory active
charcoallterunitmayalreadybeinstalled.
Instructions for transforming the hood from the ducted to the
lterversionaregiveninthismanual(see“Filterversion”).
Ducted version
Thehoodpuriestheairandexpelsitoutdoorsviaan
exhaustduct(dia.150mm)connectedtoitsoutletange.
The diameter of the exhaust tube must be equal to that of
theoutletange.
Caution! The exhaust duct is not supplied and must be
purchased separately.
When routed horizontally, the tube must be angled slightly
upwards (around 10°) to enable the air to be conveyed
outdoorsmoreeasily.Ifthehoodisttedwithcharcoal
lters,theymustrstberemoved.
Filter version
Thehoodpuriestheairandreturnsittotheroom.This
version of the hood requires installation of an accessory
activecharcoallterunit.
Thisversionrequiresanairdeector,areductionadapter
andthecharcoallter/s.Thetoptubemusthaveitsair
outlet slots uppermost.
Technical data
Model
Height
(cm)
Width
(cm)
Depth
(cm)
dia. of
exhaust tube
(cm)
GLASS 60cm 61-82 59.8 50 15/12
GLASS 90cm 61-82 89.9 50 15/12
Model code Bulb (V) Bulb draw (W) Total draw (W)
HDF6.5SAB
HDA6.5SAB
HDF7.5SAB
HDF9.5SAB
HDA9.5SAB
HDA7.5SAB
Halogen 2 x 40 185
Power Voltage Cap Dimensions
Halogen 25 W 2 x 25 W 230V G9 L40xØ14
Halogen 20 W 2 x 20 W 12V G4 L30xØ10
LED *
RiskGroup1accordingtoStandardEN62471
ThehoodsareconformingtothefollowingEC
Directives:
•“Lowvoltage”Directive2006/95/EC(12-12-2006)
•“EMC”Directive2004/108/EC(15-12-2004)
* Only available in certain models