GB
9
Troubleshooting
If the appliance does not work, before calling for Assistance (
see Assistance
), check for a solution from the following list.
Malfunctions:
The internal light does not
illuminate.
The refrigerator and the freezer do
not cool well.
The food inside the refrigerator is
beginning to freeze.
The AIR fan does not rotate.
The motor runs continuously.
The appliance makes a lot of noise.
Some of the external parts of the
refrigerator become hot.
The back wall of the refrigerator unit
is covered in frost or droplets of
water.
There is water at the bottom of the
refrigerator.
Possible causes / Solutions:
• The plug has not been inserted into the electrical socket, or not far
enough to make contact, or there is no power in the house.
• The doors do not close properly or the seals are damaged.
• The doors are opened too frequently.
• The TEMPERATURE ADJUSTMENT knob is not in the correct position
• The refrigerator or the freezer have been over-filled.
• The atmospheric temperature of the area surrounding the appliance
is lower than 14°C.
• The TEMPERATURE ADJUSTMENT knob is not in the correct
position.
• The food is in contact with the back inside wall of the refrigerator.
• The refrigerator door is open.
• The AIR system is only activated automatically when it becomes
necessary to restore perfect operational conditions inside the
refrigerator compartment.
• The door is not closed properly or is continuously opened.
• The outside ambient temperature is very high.
• The thickness of the frost exceeds 2-3 mm (
see Maintenance
).
• The appliance has not been installed on a level surface (
see
Installation
)
.
• The appliance has been installed between cabinets that vibrate and
make noise.
• The internal refrigerant makes a slight noise even when the
compressor is off. This is not a defect, it is normal.
• These raised temperatures are necessary in order to avoid the
formation of condensation on certain parts of the product.
• This shows the appliance is operating normally.
• The water discharge hole is blocked (
see Maintenance
).