Case Specifications
Model Refrigeration Average Disch. Air T~Stat Coil Fan Blade Qty. Defrosts Elec. Load (Amps) @ ~115 VAC
& Btu / Hr. Temperatures (°F) Speed Settings Type Size (in) & Evap. per day Fans Fans Case Shelf
Length (Ft.) (Total) Evap. Prod. Disch. (CFM) (°F) Pitch ( ° ) Fans Min. Qty. Eng. Eff. Std. Lights Levels
4' 1,700 6,800 20° 34° 28° 300 28° Forced 8" x 30° 1 20 4 0.33 0.60 3.6 4
Air
6' 1,700 10,200 20° 34° 28° 300 28° Forced 8" x 30° 2 20 4 0.66 1.20 3.6 4
Air
8' 1,700 13,600 20° 34° 28° 300 28° Forced 8" x 30° 2 20 4 0.66 1.20 6.04 4
Air
12' 1,700 20,400 20° 34° 28° 300 28° Forced 8" x 30° 3 20 4 0.99 1.80 8.48 4
Air
Condensing Unit Data
Set (PSI) Size Voltage Ampacity
Out In (HP) (VAC)
4' 30 50 1 208 ~ 230 13.0
6' 30 50 1
1
/2 208 ~ 230 19.0
8' 2 Units 30 50 1 208 ~ 230 13.0 ea.
12' 2 Units 30 50 1
1
/2 208 ~ 230 19.0 ea.