Replacing GIB Controller on Quest Juice Dispensers
Publication Number: 729011138INS - 2 - © 2003, IMI Cornelius Inc.
Removal of GIB Control
9. Remove plugs from GIBC by pulling connectors from rear of unit. Plugs may be difficult to remove.
(NEVER PULL ON WIRES AS THEY MAY COME LOOSE FROM CONNECTOR BODY). If con-
nector body is damaged replace with the proper connector body supplied in the kit. Refer to the
drawing in the beginning of the installation sheet for proper connector and wire locations.
10. Reverse the above procedure to reassemble machine.
CAUTION: When reinstalling the new GIBC be sure not to pinch wires between any parts of the
frame. With the side panel off inspect that the wires are free and not trapped where they could
become pinched and short out to the cabinet frame.
NOTE: It is also recommended that before reattaching the panels to the machine reinstall the
control and verify machine functions properly. If any part of the dispenser does not function
properly such as pumps, disconnect power and reinstall GIB control. Be sure connector is seated
properly in connectors.
1. Disconnect power from unit.
2. Remove dispensing nozzles.
3. To remove splash panel located at the bottom of the
unit remove two screws left and right side and slide
splash panel forward.
4. To remove top panel open door and locate two
screws at the rear of the panel. Slide top panel for-
ward to release it from the front.
5. To remove the side panels locate two screws at the
rear of the panel top and bottom and pull off.
6. Locate the plastic wire tie holding the wire harness
bundle together and cut to remove.
7. Locate the electrical box, from the front of the
machine, and remove the screw on the right side
holding it in place. Grab the left tab of the box and
pull forward.
NOTE: The connectors in the back will tend to give
some resistance when pulling on the box.
8. You will now be able to access the GBIC. To remove
slide module to the right. When box stops push up
and pull forward.