Cornelius pmnice systems Ice Maker User Manual


 
PRODUCTION CHART
AIR-COOLED
Water Temperature (˚F)
Air Temp (˚F) 50 70 80
70 46 lbs. 41 lbs. 40 lbs.
80 44 lbs. 40 lbs. 40 lbs.
90 42 lbs. 38 lbs. 35 lbs.
Series 50†
Series 200
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
ACS50SL Air-Cooled R-134a 115/60/1 15 15 110 lbs. 100 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser Capacity
Model Rate Use Consumption Water Use Storage Bin
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs. ( lbs.)
IACS224 150 25.0 10.6 n/a 77
IWCS224 145 22.0 10.5 195 77
IACS227 240 27.0 9.8 n/a 75
IWCS227 240 27.0 7.6 160 75
IACS-224 PRODUCTION CHART
AIR-COOLED WATER-COOLED
Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 251 lbs. 226 lbs. 214 lbs. 50 221 lbs. 179 lbs. 171 lbs.
70 226 lbs. 198 lbs. 177 lbs. 70 218 lbs. 165 lbs. 155 lbs.
90 167 lbs. 150 lbs. 137 lbs. 90 164 lbs. 145 lbs. 130 lbs.
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
IACS224
Air-Cooled
R-404a 115/60/1 15 15 182 lbs. 146 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
IWCS224
Water-Cooled
R-404a 115/60/1 15 15 182 lbs. 146 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
IACS227 Air-Cooled R-404a 115/60/1 20 20 230 lbs. 198 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
IWCS227
Water-Cooled
R-404a 115/60/1 20 20 230 lbs. 198 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser Capacity
Model Rate Use Consumption Water Use Storage Bin
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs. (lbs.)
ACS50 38 38.5 14.3 n/a 25
DIMENSIONS/CAPACITY
Model Nominal Cabinet
Number Capacity Dimensions Finish
ACS50 46 lbs. 15"w x 24"d x 34"h E
DIMENSIONS/CAPACITY
Model Nominal Cabinet
Number Capacity Dimensions Finish
IACS224/IWCS224 251 lbs 24"w x 24"d x 39"h Polyethylene
IACS227/IWCS227 326 lbs 27"w x 28"d x 39"h SS
†Limited lifetime warranty not applicable to this model.
ACS50
IACS227
Rated in accordance with ARI Standard 810-91 and 820-88.
Rated in accordance with ARI Standard 810-91 and 820-88.
24"
15"
34 "
28"
27 "
39"
C
U
B
E
R
S
4
IACS224
24"
24"
39"
IACS-227 PRODUCTION CHART
AIR-COOLED WATER-COOLED
Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 326 lbs. 295 lbs. 271 lbs. 50 330 lbs. 300 lbs. 270 lbs.
70 312 lbs. 290 lbs. 267 lbs. 70 310 lbs. 280 lbs. 260 lbs.
90 263 lbs. 240 lbs. 220 lbs. 90 280 lbs. 240 lbs. 230 lbs.