Cornelius TRIAD-150 Beverage Dispenser User Manual


 
3
620911101
BEVERAGE SYSTEM (IF APPLICABLE)
WARNING: Disconnect Power Before Cleaning! Do not use metal scrapers, sharp objects
or abrasives on the ice storage hopper, top cover and the agitator disk, as damage may
result. Do not use solvents or other cleaning agents, as they may attack the plastic material.
Soap solution - Use a mixture of mild detergent and warm (100 F) potable water.
Sanitizing solution - Use 1/2 ounce of household bleach in 1 gallon of potable water. Preparing the sanitizing
solution to this ratio, the required solution of 200 PPM will be obtained.
Cleaning tank - Fill clean, empty tank with a mixture of mild detergent and five (5) gallons of warm
potable water (120°F).
1. DISPENSING VALVES
Refer to addendum supplied with the unit that is applicable to the manufacturer of the valves installed
on the unit.
2. PRODUCT TUBING
Only trained and qualified persons should perform these cleaning and sanitizing procedures.
A. Sanitize tank systems, Post-Mix and Pre-Mix
a. Remove all the quick disconnects from all the tanks. Fill a suitable pail or bucket with
soap solution.
b. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon
bristle brush. (Do not use a wire brush). Rinse with clean water.
c. Prepare sanitizing solution and using a mechanical spray bottle, spray the disconnects.
Allow to air dry.
d. Using a clean, empty tank, prepare five (5) gallons of the sanitizing solution. Rinse the tank dis-
connects with approximately 9 oz. of the sanitizing solution. Close the tank.
e. Prepare cleaning tank by filling clean five (5) gallon tank with a mixture of mild detergent and po-
table water (120_F).
f. Connect a gas disconnect to the tank and then apply one of the product tubes to the cleaning
tank. Operate the appropriate valve until liquid dispensed is free of any syrup.
g. Disconnect cleaning tank and hook up sanitizing tank to syrup line and CO
2
system.
h. Energize beverage faucet until chlorine sanitizing solution is dispensed through the faucet. Flush
at least two (2) cups of liquid to ensure that the sanitizing solution has filled the entire length of
the syrup tubing.
i. Allow sanitizer to remain in lines for fifteen (15) minutes.
j. Repeat the step above, applying a different product tube each time until all tubes are filled with
the sanitizing solution.
k. For post-mix valves, remove the nozzle and syrup diffuser and clean them in a mild soap solution.
Rinse with clean water and reassemble the nozzle and syrup diffuser to the valve.
l. For pre-mix valves, disconnect all product tubes from the tank of sanitizing solution and then
open the valves to allow the pressure to be relieved. Remove the valves from the dispenser, dis-
assemble and wash thoroughly in a mild soap solution.
m. Rinse the parts in clean water, reassemble the valve and reconnect it to the dispenser.