Cornelius UCR 700 Series Ice Maker User Manual


 
4630460154
Table 1. Design Data (contd)
Water SupplyWater inlet fitting is 1/4inch SAE flare located at the top front of the Unit. The Unit is designed
to operate on water pressure between 10 PSI and 90 PSI.
Drain Overflow Line (Located at rear of the Unit) 3/8inch Flexible Tubing
Ambient Operating Temperature 40° F to 100° F
Electrical:
Unit Electrical Rating 115 VAC, 60 Hz, 15.6 Amps,
Single Phase
Recommended Electrical Supply 115 VAC, 60 hz, 20 Amps
Dedicated 3Wire
Grounded Circuit
SPECIFICATION CHART
Models Condensing
Uit
VAC HZ PH Wire Comp.
RLA
Fan
A
GRMTR
A
Refrigerant
Circuit
F
g
Unit RLA Amps Amps
Oz. Type
Fuse
UCR700A Air Cooled 115 60 1 2 12 1.6 2 24 R404A 20
UCR700W Water Cooled 115 60 1 2 12 N/A 2 13 R404A 20
650
600
550
500
450
400
350
Capacity Lbs./24 hr.
Capacity Lbs./24 hr.
90 80 70 60 50
Water Temperature Deg. F
Air Temperature Deg. F
50 70 90 100
UC700