Imperial 75 lb. (41 L. )Fryers
Imperial Commercial Cooking Equipment
1128 Sherborn Street Corona, CA 92879 800.343.7790 Ph: 951.281.1830 Fx: 951.281.1879
www.imperialrange.com E-mail: imperialsales@imperialrange.com
Standard Exterior Finish Specifications
Front, sides, door, stub back and basket hanger shall be
constructed of stainless steel with welded and finished
stainless steel seams. Stainless steel legs shall be plate
mounted and include non-marking feet.
Frypot Specifications
All precision welded stainless steel vessel shall be
constructed of heavy 16 gauge stainless steel. Vessel shall
have a large foam area to prevent overflow. All vessel
edges shall be radius formed for added durability. Frying
area shall be 18" x 18" (457 x 457) with a 75 lbs. (41 L.)
oil capacity. There shall be five 14 gauge stainless steel,
fully immersed heat transfer tubes for maximum efficiency.
Heat retaining baffles and deflectors shall be inside of tubes
and easily removed for cleaning. Tube joints shall be weld-
ed on the outside of specially drawn fry vessels to prevent
leaks. Gas output shall be 175,000 BTU/hr (51 KW).
Snap acting thermostat shall have a 200
o
F - 400
o
F
(93
o
C - 204
o
C) temperature range. Fail-safe high limit
control shall shut off all gas if oil temperature exceeds
435
o
F. (224
o
C). Safety pilot shall be 100% shut off.
Large cool zone beneath tubes shall capture food and
breading particles and keep them out of the frying area to
improve food taste and prolong oil life. Fine mesh crumb
screen shall be removable. Unit shall include removable
drain pipe and clean out rod. Drain shall be a 1
1
/4" (32) full
port drain valve for quick draining.
Gas
Manifold pressure is 4" W.C. for natural gas or 11" for propane
gas. Manifold size
3
/4" NPT.
3
/4" pressure regulator supplied
with equipment to be installed at time of connection. Specify
type of gas and elevation if over 2,000 ft. (610 m).
Clearance
For use only on non-combustible floors. Legs or casters are
required for non-combustible floors; or 2" (51) overhang is
required when curb mounted. Provide 0" clearance from
non-combustible surfaces and 6" (152) from combustible
surfaces.
Optional Items
Rear gas pressure regulator
Portable oil filter unit
Fryer drain station with a storage cabinet
Quick disconnect hose and restraining device
Stainless steel strip to cover between fryers
Various size fry baskets
6" (152) swivel casters (front two casters are locking)
Stainless steel backguard
Optional Fryer/Filter Systems
Pre-packaged systems with matching cabinet and
built-in filter and pan
Stainless steel dump station and food warmer
System options include solid state thermostat control,
computer fry control and basket lifts
75 lb. (41 L.) Fryers
Oil Capacity Gas Output Ship Wt.
Model# Description Lbs. (Liters) BTU (KW) (Kg.) Lbs.
IFS-75 Stainless Steel Frypot 75 (41) 175,000 (51) (122) 270
IFS-75SS Range Match with Stainless Steel Frypot 75 (41) 175,000 (51) (122) 270
All measurements in ( ) are metric equivalents.
Crated Dimensions: 36" (891) d x 19
1