3
GB
DATA PLATE
Dimensions
width cm 43.5
height cm 32
depth cm 40
Volume
lt. 56
Electrical
connections
voltage: 230-240V ~ 50Hz
maximum power absorbed 2800-
3000W
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens.
Norm EN 50304
Energy consumption for Natural
convection – heating mode:
Traditional mode
Declared energy consumption for
Forced convection Class – heating
mode: Baking
This appliance conforms to the
following European Economic
Community directives:
-2006/95/EEC of 12/12/06 (Low
Voltage) and subsequent
amendments;
- 89/336/EEC of 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments;
- 93/68/EEC of 22/07/93 and
subsequent amendments.
- 2002/96/EC
GREEN &
YELLOW
BROWN
BLUE
13 amp fuse
CROSS-BAR
CORD GRIP
How to connect an alternative plug
The wires in this mains
lead are coloured in
accordance with the
following code:
BLUENEUTRAL (N)
BROWN LIVE (L)
GREEN AND YELLOW
EARTH (E)
Disposing of the appliance
When disposing of the appliance please remove the
plug by cutting the mains cable as close as
possible to the plug body and dispose of it as
described above.
! The plug and socket must be easily accessible.
if the cooker is connected directly to the mains, an
omnipolar circuit-breaker with a minimum opening of
3 mm between the contacts, suitable for the load
indicated and complying with current directives,
must be installed between the appliance and the
mains (the earthing wire must not be interrupted by
the circuit-breaker). The power supply cable must be
positioned so that it does not exceed room
temperature by 50°C at any point of its length.
Before making the connection check that:
the circuit breakers or fuses of the home system
can support appliance load (seedata plate);
the power supply system has an efficient earthing
connection which complies with the provisions of
current regulations and the law;
there is easy access to the socket or the
omnipolar circuit-breaker once the cooker has
been installed.
! do not use reducers, adapters or shunts as these
could cause heating or burning.
Connection n° 2
Disposing of the plug.
! THIS APPLIANCE MUST BE EARTHED.
Ensure that before disposing of the plug itself, you
make the pins unusable so that it cannot be
accidentally inserted into a socket. Instructions for
connecting cable to an alternative plug:
! the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow -Earth
Blue -Neutral
Brown -Live
If the colours of the wires in the mains lead do not
correspond with the coloured markings identifying
the terminals in your plug, proceed as follows.
Connect Green & Yellow wire to terminal marked E
or 6 or coloured Green or Green & Yellow.
Connect Brown wire to terminal marked L or
coloured Red. Connect Blue wire to terminal marked
N or coloured Black. If a 13 amp plug (BS 1363) is
used it must be fitted with a 13 amp fuse.
A 15 amp plug must be protected by a 15amp
fuse, either in the plug or adaptor or at the
distribution board.If you are in any doubt about the
electrical supply to your machine, consult a qualified
electrician before use.