10
GB
Installation
LN
12345
LN
12345
L1L2
12345
Built-in Installation
This oven can be built into any standard space in cabinetry
whose dimensions meet European standards.
No special precautions are needed for its installation,
due to:
- Reinforced insulation which limits heat exchanges,
- Frontal ventilation requiring no air inlet.
Installation must be carried out by a qualified professional
and meet all applicable safety standards. The guarantee
for the appliance does not cover any damage caused by
improper installation.
Proper installation is also required to ensure the users’
safety and a long useful life for the appliance.
585
588
550
560
545
23
595
3
To fix the oven in place, open the door and fasten the 2
screws (provided with the appliance) in the 2 correspond-
ing holes.
Power connection
Before connecting the power, the meter must be checked
to verify the conditions for the delivery of the available
electrical energy — number of phases, voltage, maximum
power necessary — which must be compatible with the
Indesit appliance in question.
Indesit ovens can be adapted to the following
electrical installations:
Appliance meeting CE standards according to directives:
DBT 73/23 CEE modified by directive 93/68/
CEE CEM 89/336/CEE
There are two ways to connect the oven during
installation:
- By using an electrical plug,
- By using a connection panel.
In both cases, refer to the table above for the minimum
diameters of the wires and the calibration of the protec-
tive components according to the type of connection.
If the appliance is connected using a connection panel,
an omnipolar switchgear with a minimum distance be-
tween contacts of 3 mm must be installed upstream from
the connection of the appliance.
We recommend that you use a power cord that is long
enough to allow the oven to be pulled out for maintenance
operations. Use only cables of HAR - H 05 - RRF quality
equipped with a plug that complies with the regulations of
the country where the installation takes place. The plug
must be accessible.
Before any maintenance or repair operation, includ-
ing replacing the light bulb, you must first discon-
nect the appliance.
It is hazardous to operate an appliance that has not
been properly earthed.
Important: After connecting the appliance to the flexible
cable, tighten all the screws of the terminal plate.
Electrical connection
Voltage
Frequency
Power
Fuse
FR-BE-CH-DE-DK-ES-IL-GB-IT-NL-AT-GR-
RE-MA-LU-IE-FI-PT-NZ
SE-IS
230 V 1+N 50 Hz
2,99 kW
16 A
1,5 mm
FR-BE-NO
230 V 2 50 Hz
2,99 kW
16 A
1,5 mm
CY-MT-AU-NZ-KW
240 V 1+N 50 Hz
3,26 kW
16 A
1,5 mm