8 GB
Electrical connection and working test
• Before connecting to the mains supply ensure that the mains voltage corresponds
with the voltage on the rating plate inside the hood.
• Connect the cooker hood to the mains via a double pole switch which has 3 mm
clearance between the contacts.
• The appliance must be earthed.
• Once the electrical connection has been completed, check that worktop illumination,
motor and speed work properly.
Fitting the telescopic chimney stack
• Fit the two plastic supports provided to the top part of the hood.
• To fit the upper section item S first expand the chimney slightly to allow it to fit over the
wall brackets (item 2 fig. 1) and then secure the upper section using the 4 screws supplied.
• The lower section item I of the chimney stack should be fitted between the lower bracket
2 and the wall.
• Fix the U-shaped section to the plastic supports, using two of the screws provided in the
bag of accessories (fig. 7).
Part 2
a
OPERATION AND MAINTENANCE INSTRUCTIONS
Fig. 7
S
I